Determinación del poder corneal con un tomógrafo corneal luego de cirugía refractiva con láser excimer

dc.contributor.apolounabCamacho López, Paul Anthony [paul-anthony-camacho-lópez]
dc.contributor.authorJaramillo, Luis Carlosspa
dc.contributor.authorGalvis Ramírez, Virgiliospa
dc.contributor.authorTello Hernández, Alejandrospa
dc.contributor.authorCamacho López, Paul Anthonyspa
dc.contributor.authorCastillo, Ángelaspa
dc.contributor.authorPareja, Luisspa
dc.contributor.cvlacGalvis Ramírez, Virgilio [0000552453]
dc.contributor.cvlacTello Hernández, Alejandro [0001009125]
dc.contributor.cvlacCamacho López, Paul Anthony [0000323578]
dc.contributor.googlescholarGalvis Ramírez, Virgilio [CZOaBDoAAAAJ]
dc.contributor.googlescholarTello Hernández, Alejandro [puxZHKYAAAAJ]
dc.contributor.googlescholarCamacho López, Paul Anthony [-u8d7_QAAAAJ]
dc.contributor.linkedinCamacho López, Paul Anthony [paulcamachomdepi]
dc.contributor.orcidGalvis Ramírez, Virgilio [0000-0001-5081-0720]
dc.contributor.orcidCamacho López, Paul Anthony [0000-0002-6233-9582]
dc.contributor.researchgateGalvis Ramírez, Virgilio [profile/Virgilio_Galvis]
dc.contributor.researchgateTello Hernández, Alejandro [profile/Alejandro_Tello]
dc.contributor.researchgateCamacho López, Paul Anthony [profile/Paul_Camacho_Lopez]
dc.contributor.researchgroupGrupo de Investigaciones Clínicasspa
dc.contributor.scopusGalvis Ramírez, Virgilio [55963715000]
dc.contributor.scopusTello Hernández, Alejandro [6603664598]
dc.contributor.scopusCamacho López, Paul Anthony [16047325700]
dc.date.accessioned2020-10-27T14:19:25Z
dc.date.available2020-10-27T14:19:25Z
dc.date.issued2018-11-19
dc.description.abstractLa determinación del poder corneal, después de la cirugía refractiva con láser excimer, es difícil. Diferentes alternativas con el uso de tomógrafos corneales se han utilizado para esta medición. Objetivo. Evaluar diversos métodos de determinación del poder corneal en pacientes operados de cirugía fotorrefractiva, incluyendo pruebas diagnósticas con medidas cuantitativas. Metodología. Estudio retrospectivo de pacientes operados de cirugía fotorrefractiva que tuvieran resultados refractivos y tomografía corneal post-operatoria al menos diez semanas luego de cirugía. Resultados. En los ojos miopes se encontraron diferencias significativas en el valor determinado por la queratometría derivada de la historia clínica al compararla con la queratometría manual promedio postoperatoria, la queratometría simulada y el Mean Pupil Power del tomógrafo Sirius®. Por otra parte, al promediar la queratometría manual promedio postoperatoria con el Mean Pupil Power postoperatorio (valor denominado Kpop promedio 1) y compararla con la queratometría derivada por el método de la historia clínica, no se observaron en los pacientes miopes diferencias estadísticamente significativas. Asimismo, al promediar la queratometría simulada postoperatoria del equipo Sirius® con el Mean Pupil Power postoperatorio (valor denominado Kpop promedio 2) y compararla con la queratometría derivada por el método de la historia clínica tampoco se observaron en los pacientes miopes diferencias estadísticamente significativas. Por otro lado, en los ojos hipermétropes y con astigmatismo mixto, los promedios de los errores del Mean Pupil Power postoperatorio, con respecto a la queratometría derivada por el método de la historia clínica, no fueron significativamente diferentes de los errores al comparar la Kpop promedio 1 y la Kpop promedio 2con la queratometría derivada por el método de la historia clínica. Conclusiones. En ojos miopes las determinaciones del poder corneal postoperatorio con las Kpop promedio 1 y Kpop promedio 2 se aproximan más a la queratometría derivada por el método de la historia clínica que a las mediciones de la queratometría manual promedio postoperatoria, la queratometría simulada postoperatoria o el Mean Pupil Power del equipo Sirius®. [Jaramillo LC, Galvis V, Tello A, Camacho PA, Castillo A, Pareja LA. Determinación del poder corneal con un tomógrafo corneal luego de cirugía refractiva con láser excimerspa
dc.description.abstractenglishIntroduction. The determination of corneal power, after excimer laser refractive surgery, is difficult. Different alternatives with the use of corneal tomographs have been used for this measurement. Objective. To evaluate various methods of determination of corneal power in patients undergoing photorefractive surgery, including diagnostic tests with quantitative measurements. Methodology. This is a retrospective observational study. We included patients undergoing photorefractive surgery with refractive results and postoperative corneal tomography taken at least ten weeks after surgery. Results. In the myopic eyes significant differences were found in the value determined by the keratometry derived from the clinical history when compared with the average postoperative manual keratometry, the simulated keratometry and the Mean Pupil Power of the Sirius® tomograph. On the other hand, when averaging the average postoperative manual keratometry with the postoperative Mean Pupil Power (value called Kpop average 1) and comparing it with the keratometry derived by the clinical history method, no statistically significant differences were observed in the myopic patients. Likewise, when averaging the simulated postoperative keratometry of the Sirius® equipment with the postoperative Mean Pupil Power (value called “Kpopaverage 2”) and comparing it with the keratometry derived by the method of the clinical history, no statistically significant differences were observed in the myopic patients. On the other hand, in hyperopic eyes and with mixed astigmatism, mean errors of the postoperative Mean Pupil Power, with respect to the keratometry derived by the clinical history method, were not significantly different from the errors when comparing the “Kpop average 1” and the “Kpop average 2” with the keratometry derived by the clinical history method. Conclusions. In myopic eyes the postoperative corneal power determinations with the “Kpop average 1” and “Kpop average 2” are closer to the keratometry derived by the clinical history method than to the measurements of the average postoperative manual keratometry, the postoperative simulated keratometry or the Mean Pupil Power of the Sirius® equipment. [Jaramillo LC, Galvis V., Tello A., Camacho PA, Castillo A., Pareja LA. Corneal power determination with corneal tomography after refractive surgery with excimer laser.eng
dc.format.mimetypeapplication/pdfspa
dc.format.mimetypeApplication/pdfspa
dc.identifier.doi10.29375/01237047.2397
dc.identifier.instnameinstname:Universidad Autónoma de Bucaramanga UNABspa
dc.identifier.issn2382-4603
dc.identifier.issn0123-7047
dc.identifier.repourlrepourl:https://repository.unab.edu.co
dc.identifier.urihttp://hdl.handle.net/20.500.12749/9957
dc.language.isospaspa
dc.language.isoengspa
dc.publisherUniversidad Autónoma de Bucaramanga UNAB
dc.publisher.facultyFacultad Ciencias de la Salud
dc.publisher.programPregrado Medicinaspa
dc.relationhttps://revistas.unab.edu.co/index.php/medunab/article/view/2397/2879
dc.relationHttps://revistas.unab.edu.co/index.php/medunab/article/view/2397/2880
dc.relation.referencesHolladay JT. Cataract surgery in patients with previous keratorefractive surgery (RK, PRK, and LASIK). Ophthalmic Practice. 1997;15:238–44 p
dc.relation.referencesHaigis W. Intraocular lens calculation after refractive surgery. European Ophthalmic Review. 2012;6(1):21-4. doi: 10.17925/EOR.2012.06.01.21
dc.relation.referencesKalyani SD, Kim A, Ladas JG. Intraocular lens power calculation after corneal refractive surgery. Curr Opin Ophthalmol. 2008;19(4):357-62. doi: 10.1097/ICU.0b013e3282fec43e
dc.relation.referencesHolladay JT, Galvis V, Tello A. Re: Wang et al.: Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery (Ophthalmology 2015;122:2443-9) Ophthalmology. 2016;123(9):55-6. doi: 10.1016/j.ophtha.2016.02.038
dc.relation.referencesHolladay JT. Consultations in refractive surgery: IOL calculations following radial keratotomy surgery. Refract Corneal Surg. 1989;5: p. 203
dc.relation.referencesSavini G, Calossi A, Camellin M, Carones F, Fantozzi M, Hoffer KJ. Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery. J Cataract Refract Surg. 2014;40(7):1109-15. doi: 10.1016/j.jcrs.2013.11.032
dc.relation.referencesHolladay JT, Hill WE, Steinmueller A. Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery. J Refract Surg. 2009;25(10):862-8. doi: 10.3928/1081597X-20090917-07
dc.relation.referencesSónego S, López G, Beaujon OV, Arce CG, Schor P, Campos M. A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis. Arch Ophthalmol. 2004;122(2):159-66. doi: 10.1001/archopht.122.2.159
dc.relation.referencesGelender H. Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis). Trans Am Ophthalmol Soc. 2006;104:402-13
dc.relation.referencesBrooks CW. High-Powered Lenses. In: Understanding Lens Surfacing. Butterworth-Heinemann. Stoneham, United States. 1992. p. 241–245. doi: 10.1016/B978-0-7506-9177-2.50019-9
dc.relation.referencesAltman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Journal of the Royal Statistical Society. 1983;32(3):307–17. doi: 10.2307/2987937
dc.relation.referencesBland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;327(8476):307-10. doi: 10.1016/S0140-6736(86)90837-8
dc.relation.referencesBland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999; 8(2):135-60.doi: 10.1177/096228029900800204
dc.relation.referencesGiavarina D. Understanding Bland Altman analysis. Biochem Med. 2015;25(2):141–151. doi: 10.11613/BM.2015.015
dc.relation.referencesGalvis V, Tello A, Jaramillo LC, Castillo AM, Pareja LA, Camacho PA. Cambios corneales producidos por la cirugía refractiva con excimer láser: revisión de tema. MÉD. UIS. 2017;30(1):99-105. doi: 10.18273/revmed.v30n1-2017010Luis Carlos Jaramillo, MD., Esp., Virgilio Galvis, MD., Esp., PhD., Alejandro Tello, MD., Esp., PhD., Paul Anthony Camacho, MD., MSc., Ángela Castillo, MD., Esp., Luis A. Pareja, MD..Vol 21(1): 16-30, abril - julio 2018
dc.relation.urihttps://revistas.unab.edu.co/index.php/medunab/article/view/2397
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.sourceMedUNAB; Vol. 21 Núm. 1 (2018): Abril - julio 2018: Topografía de la Córnea, Indicadores Bibliométricos, Calidad de Vida; 16-45
dc.subject.keywordsCorneal topographyeng
dc.subject.keywordsCorneaeng
dc.subject.keywordsPhotorefractive keratectomyeng
dc.subject.keywordsExcimer laserseng
dc.subject.keywordsRefractive surgical procedureseng
dc.subject.keywordsRefractive errorseng
dc.subject.lembCiencias médicas
dc.subject.lembTecnología médica
dc.subject.lembInvestigación médica
dc.subject.proposalTopografía de la córnea
dc.subject.proposalCórnea
dc.subject.proposalQueratectomía fotorrefractiva
dc.subject.proposalLáseres de excímeros
dc.subject.proposalProcedimientos quirúrgicos refractivos
dc.subject.proposalErrores de refracción
dc.titleDeterminación del poder corneal con un tomógrafo corneal luego de cirugía refractiva con láser excimer
dc.title.translatedCorneal power determination with corneal tomography after refractive surgery with excimer laser
dc.title.translatedDeterminação da potência corneana com uma topografia de córnea após cirurgia refrativa com excimer láser
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.driverinfo:eu-repo/semantics/article
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localArtículospa
dc.type.redcolhttp://purl.org/redcol/resource_type/ART

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
2018_Determinación_del_poder_corneal_con_un_tomógrafo.pdf
Tamaño:
1.27 MB
Formato:
Adobe Portable Document Format
Descripción:
Articulo