Sistema de monitorización basado en RFID para dispositivos médicos del servicio de cirugía oftalmológica de una institución prestadora de servicios de salud de alta complejidad

dc.contributor.authorBarón Santamaría, Daniel Alberto
dc.contributor.authorMorales Cordero, Mario Fernando
dc.contributor.authorAmado Forero, Lusvin Javier
dc.contributor.cvlacMorales Cordero, Mario Fernando [0001460371]spa
dc.contributor.cvlacAmado Forero, Lusvin Javier [0001376723]spa
dc.contributor.googlescholarAmado Forero, Lusvin Javier [dqrfjJMAAAAJ]spa
dc.contributor.orcidMorales Cordero, Mario Fernando [0000-0001-7536-3162]spa
dc.contributor.orcidAmado Forero, Lusvin Javier [0000-0001-5104-9080]spa
dc.contributor.researchgateAmado Forero, Lusvin Javier [Lusvin-Amado]spa
dc.contributor.researchgroupSemilleros de Investigación UNABspa
dc.coverage.campusUNAB Campus Bucaramangaspa
dc.coverage.spatialBucaramanga (Santander, Colombia)spa
dc.coverage.temporal2020spa
dc.date.accessioned2023-11-12T18:22:05Z
dc.date.available2023-11-12T18:22:05Z
dc.date.issued2020-12
dc.description.abstractMúltiples aplicaciones tienen los sistemas RFID en el ámbito hospitalario para garantizar la trazabilidad, ubicación e identificación de activos en tiempo real. La implementación de estos sistemas ayuda a optimizar procesos como ahorrar tiempo al personal de salud para localizar dispositivos médicos, aumentar la vigilancia de los dispositivos y tener un manejo más efectivo y seguro de inventario. Se presenta una problemática en el área de cirugía oftalmológica de Fundación FOSUNAB, esta es la falta de un sistema que garantice el seguimiento de los dispositivos médicos en tiempo real, con el fin de aumentar la vigilancia de los dispositivos médicos, su utilidad y cumplimiento con las normas impuestas por zona franca. Por lo cual, se propone desarrollar un sistema de monitorización basado en RFID para los dispositivos médicos del servicio de cirugía oftalmológica de una IPS de alta complejidad. Para el desarrollo de este sistema se realiza en tres principales ítems. El primero es la construcción del sistema electrónico donde se tienen en cuenta los requerimientos del sistema de monitoreo, ensamble de los equipos y realizan pruebas de estos; El segundo es el desarrollo de la aplicación web para la cual se establecen los requerimientos funcionales y no funcionales de la aplicación; El tercero y último ítem es la evaluación del sistema de monitorización, donde se realiza la instalación del sistema en cirugía oftalmológica y posteriormente las pruebas. El sistema tiene una detección correcta del 80,42% de los tags que pasan por el área monitorizada. Lo que se busca es que el sistema tenga una detección efectiva del 100% de los tags y por ende de los dispositivos médicos, sin embargo, variables como el posicionamiento de la antena, interferencias de radiofrecuencias en el entorno, periodos de latencia en la detección del tag; afectan el performance del sistema y se debe controlar lo mejor posible para llegar a un 100% de detección efectiva de los tags.spa
dc.description.abstractenglishMultiple applications have in-hospital RFID systems to ensure the traceability, location and identification of assets in real time. The implementation of these systems helpsto optimize processessuch as saving time for health personnel to locate medical devices, increase device surveillance and have a more effective and safe inventory management. There is a problem in the area of ophthalmic surgery of Fundación FOSUNAB, this is the lack of a system that guarantees the monitoring of medical devices in real time, in order to increase the monitoring of medical devices, their usefulness and compliance with the rules imposed by the free zone. Therefore, it is proposed to develop a monitoring system based on RFID for the medical devices of the ophthalmic surgery service of a highly complex IPS. For the development of this system is carried out in three main items. The first is the construction of an electronic system that takes into account the requirements of the monitoring system, assembling and testing equipment; The second is the development of the web application for which the functional and nonfunctional requirements of the application are established; The third and final item is the evaluation of the monitoring system, where the installation of the system is performed in ophthalmological surgery and later tests. The system has a correct detection of 80.42% of the tags that pass through the monitored area. What is sought is that the system has an effective detection of 100% of the tags and therefore of the medical devices, however, variables such as the positioning of the antenna, radio frequency interference in the environment, latency periods in the detection of the tag; affect the performance of the system and should be controlled as best as possible to reach 100% effective detection of tags.spa
dc.description.learningmodalityModalidad Presencialspa
dc.format.mimetypeapplication/pdfspa
dc.identifier.instnameinstname:Universidad Autónoma de Bucaramanga - UNABspa
dc.identifier.issnISSN 2344-7079spa
dc.identifier.reponamereponame:Repositorio Institucional UNABspa
dc.identifier.repourlrepourl:https://repository.unab.edu.cospa
dc.identifier.urihttp://hdl.handle.net/20.500.12749/22731
dc.language.isospaspa
dc.publisher.deparmentSistema de Investigación SIUNABspa
dc.publisher.facultyFacultad Ingeniería
dc.publisher.grantorUniversidad Autónoma de Bucaramanga UNABspa
dc.publisher.programPregrado Ingeniería Biomédica
dc.relation.ispartofseriesGeneración Creativa : Encuentro de Semilleros de Investigación UNABspa
dc.relation.references[1] C. Tim, “NOW UI KIT A BEUTIFUL BOOSTRAP 4”, 2020. [En línea]. Disponible en: https://demos.creativetim.com/now-ui-kit/index.html.spa
dc.relation.references[2] R. E. Walpole, R. H. Myers, S. L. Myers, y K. Ye, Probabilidad y estadídtica para ingeniería y ciencias, núm. 1. 2012spa
dc.relation.references[3] A. N. Shirehjini, A. Yassine, y S. Shirmohammadi, “Equipment location in hospitals using RFID-based positioning system”, IEEE Trans. Inf. Technol. Biomed., vol. 16, núm. 6, pp. 1058–1069, 2012.spa
dc.relation.references[4] [2] N. González, A. Capli, M. S. C. Barúa, y D. S. C. Villalba, “Monitoreo de Inventario en Tiempo Real utilizando RFID”, pp. 1–23, 2014.spa
dc.relation.references[5] J. H. Rubio Plazas y J. M. Rodríguez, “Diseño de un sistema de gestión para la supervisión e identificación de equipos médicos por medio de tecnología RFID en hospitales”, Ing. y Región, vol. 8, pp. 49–58, 2011.spa
dc.relation.references[6] L. Reina, A. Balcucho, y A. Martínez-Amariz, “Development of an inventory system for the control of fixed assets based on RFID technology”, J. Phys. Conf. Ser., vol. 1126, núm. 1, pp. 8–12, 2018.spa
dc.relation.urihttp://hdl.handle.net/20.500.12749/14245
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rights.localAbierto (Texto Completo)spa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.sourceBarón, D. A., Morales, M. F. & Amado, L. J. (2020). Sistema de monitorización basado en RFID para dispositivos médicos del servicio de cirugía oftalmológica de una institución prestadora de servicios de salud de alta complejidad. Recuperado de: http://hdl.handle.net/20.500.12749/22731spa
dc.subject.keywordsHospital clinical engineeringspa
dc.subject.keywordsBiomaterialsspa
dc.subject.keywordsBiomechanicsspa
dc.subject.keywordsInvestigationspa
dc.subject.keywordsBioinstrumentationspa
dc.subject.keywordsRFIDspa
dc.subject.keywordsMedical devicespa
dc.subject.keywordsTraceabilityspa
dc.subject.keywordsTagspa
dc.subject.lembIngeniería clínica hospitalariaspa
dc.subject.lembBiomaterialesspa
dc.subject.lembBiomecánicaspa
dc.subject.lembInvestigaciónspa
dc.subject.proposalBioinstrumentaciónspa
dc.subject.proposalRFIDspa
dc.subject.proposalDispositivo médicospa
dc.subject.proposalTrazabilidadspa
dc.subject.proposalTagspa
dc.titleSistema de monitorización basado en RFID para dispositivos médicos del servicio de cirugía oftalmológica de una institución prestadora de servicios de salud de alta complejidadspa
dc.title.translatedRFID based monitoring system for medical devices of the ophthalmic surgery service from an institution providing high-quality health services complexityspa
dc.typeConferenceeng
dc.type.coarhttp://purl.org/coar/resource_type/c_f744
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
dc.type.driverinfo:eu-repo/semantics/conferenceProceedingsspa
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersionspa
dc.type.localMemoria de eventosspa
dc.type.redcolhttp://purl.org/redcol/resource_type/EC_AC

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
2020_Articulo_Baron_Santamaria_Daniel_Alberto.pdf
Tamaño:
302.79 KB
Formato:
Adobe Portable Document Format
Descripción:
Artículo

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
829 B
Formato:
Item-specific license agreed upon to submission
Descripción: