Desarrollo de un prototipo de sistema para el telecontrol y televigilancia de temperatura de incubadora abierta de una IPS de alta complejidad

dc.contributor.advisorAmado Forero, Lusvin Javier
dc.contributor.advisorMorales Cordero, Mario Fernando
dc.contributor.advisorEcheverria Gómez, Carlos Raúl
dc.contributor.apolounabAmado Forero, Lusvin Javier [lusvin-javier-amado-forero]spa
dc.contributor.apolounabMorales Cordero, Mario Fernando [mario-fernando-morales-cordero]spa
dc.contributor.authorYi Villamizar, Carlos Daniel
dc.contributor.cvlacAmado Forero, Lusvin Javier [0001376723]spa
dc.contributor.cvlacMorales Cordero, Mario Fernando [0001460371]spa
dc.contributor.googlescholarAmado Forero, Lusvin Javier [dqrfjJMAAAAJ]spa
dc.contributor.orcidAmado Forero, Lusvin Javier [0000-0001-5104-9080]spa
dc.contributor.orcidMorales Cordero, Mario Fernando [0000-0001-7536-3162]spa
dc.contributor.researchgateAmado Forero, Lusvin Javier [Lusvin_Amado]spa
dc.coverage.campusUNAB Campus Bucaramangaspa
dc.coverage.spatialBucaramanga (Santander, Colombia)spa
dc.date.accessioned2024-08-05T19:36:00Z
dc.date.available2024-08-05T19:36:00Z
dc.date.issued2024-07-23
dc.degree.nameIngeniero Biomédicospa
dc.description.abstractLas incubadoras neonatales son dispositivos médicos esenciales en las áreas pediátricas de los hospitales, ya que son equipos de soporte vital a pacientes que nacen de manera prematura o con alguna patología. Estos equipos mantienen al paciente en un ambiente controlado para la observación y cuidado, monitoreando parámetros biológicos para garantizar la seguridad en su estancia en el equipo. Normalmente la monitorización de signos vitales se realiza mediante sensores y electrodos que se mantienen en contacto directo al paciente y son visualizados únicamente en la incubadora, cualquier anormalidad en el parámetro será indicada por un sistema de alarmas instalado en la misma. El objetivo de este proyecto es desarrollar un software basado en IoT capaz de monitorear los parámetros del paciente de manera remota y llevar trazabilidad del paciente durante su estancia en la incubadora, además de mostrar cualquier anormalidad o alarma que se presente y así permitir la detección temprana de eventos potencialmente mortales. Este proyecto se centrará en la obtención, envío y comunicación de datos de los parámetros del paciente hacia un servidor local que posteriormente serán visualizados en una interfaz para el personal de servicio del área.spa
dc.description.abstractenglishNeonatal incubators are essential medical devices in pediatric areas of hospitals, as they are life-support equipment for patients who are born prematurely or with some pathology. These devices maintain the patient in a controlled environment for observation and care, monitoring biological parameters to ensure safety during their stay in the equipment. Typically, vital sign monitoring is performed using sensors and electrodes that are in direct contact with the patient and are only displayed in the incubator; any abnormality in the parameter will be indicated by an alarm system installed therein. The objective of this project is to develop IoT-based software capable of remotely monitoring patient parameters and tracking the patient during their stay in the incubator, in addition to displaying any abnormalities or alarms that occur and thus enabling early detection of potentially life-threatening events. This project will focus on obtaining, sending, and communicating patient parameter data to a local server, which will then be displayed in an interface for area service personnel.spa
dc.description.degreelevelPregradospa
dc.description.learningmodalityModalidad Presencialspa
dc.description.tableofcontentsCapítulo I - Aspectos generales 11 Descripción del problema 11 Justificación del problema 13 Objetivo general 14 Objetivos específicos 14 Capitulo II - Marco teórico y Estado de arte 15 Marco teórico 15 Incubadora neonatal 15 Tipos en incubadoras: 15 IoT 16 Control de temperatura 16 Televigilancia 16 Telecontrol 17 Estado de arte 18 Capitulo III – Metodología 22 Capitulo IV – Resultados y Análisis de Resultados 24 Resultados 24 Primera Fase. Diseño de software 24 Segunda Fase. Implementación de software 38 Tercera Fase. Pruebas de funcionalidad mediante equipos patrón 50 Capitulo V – Conclusiones y recomendaciones 56 Conclusiones 56 Recomendaciones 58 Bibliografía 59spa
dc.format.mimetypeapplication/pdfspa
dc.identifier.instnameinstname:Universidad Autónoma de Bucaramanga - UNABspa
dc.identifier.reponamereponame:Repositorio Institucional UNABspa
dc.identifier.repourlrepourl:https://repository.unab.edu.cospa
dc.identifier.urihttp://hdl.handle.net/20.500.12749/25925
dc.language.isospaspa
dc.publisher.facultyFacultad Ingenieríaspa
dc.publisher.grantorUniversidad Autónoma de Bucaramanga UNABspa
dc.publisher.grantorUniversidad Autónoma de Bucaramanga UNABspa
dc.publisher.programPregrado Ingeniería Biomédicaspa
dc.publisher.programidIBM-1788
dc.publisher.programidIMK-1789
dc.relation.referencesAmazon. (s.f.). AWS. Recuperado el 25 de Septiembre de 2023, de https://aws.amazon.com/es/what-is/iot/spa
dc.relation.referencesAshish, B. (2017). Temperature monitored IoT based smart incubator. International conference on I-SMAC (IoT in Social, Mobile, Analytics and Cloud).spa
dc.relation.referencesde Oliveira Filho, J. I., Almeida, O. d., Yousef, N., & Salama, K. N. (22019). Non-invasive IoT sensing and monitoring system for neonatal care. 31st International Conference on Microelectronics.spa
dc.relation.referencesFilho, J. I., & Almeida, O. d. (2017). Cloud-based monitoring system and risk management for premature newborns. 2nd International Symposium on Instrumentation Systems, Circuits and Transducers.spa
dc.relation.referencesGovindaraj, V., Thiagarajan, A., Uthirapathi, S., Murugiah, A. S., & Jeevagan, D. D. (2021). Emergency Alert System for Neonatal Unit using IoT. 3rd International Conference on Advances in Computing, Communication Control and Networking.spa
dc.relation.referencesGPT-3], C. [. (2023). OpenAI. Recuperado el 25 de Septiembre de 2023, de https://chat.openai.com/spa
dc.relation.referencesInstituto ECRI. (13 de 12 de 2021). El Hospital. Obtenido de https://www.elhospital.com/es/noticias/incubadoras-pediatricasspa
dc.relation.referencesJavier Jules. (28 de 08 de 2018). RCN Radio. Obtenido de https://www.rcnradio.com/recomendado-del-editor/bebes-quemados-en-incubadoras-casos-recurrentes-en-colombiaspa
dc.relation.referencesKalaiyarasi, M., Kaushik, S., & Saravanan, R. (2021). Infant Health Monitoring and Security System using IoT. Smart Technologies, Communication & Robotics.spa
dc.relation.referencesKoli, M., Ladge, P., Prasad, B., Boria, R., & Balur, N. J. (2018). Intelligent Baby Incubator. Second International Conference on Electronics, Communication and Aerospace Technology.spa
dc.relation.referencesMartínez, A. W., Cáceres, F. D., & Martínez, K. F. (2023). IoT-Based Neonatal Incubator Monitoring System. IEEE Latin American Electron Devices Conference.spa
dc.relation.referencesMedehal, A., Annaluru, A., Bandyopadhyay, S., & Chandar, T. (2021). Portable Smart Neonatal Incubator with Improvised Alarm System. IEEE International Conference on Industry 4.0, Artificial Intelligence, and Communications Technology.spa
dc.relation.referencesMuñoz Juanias, D. A. (2020). SISTEMA PARA MONITOREO Y SUPERVISIÓN DE VARIABLES Y CONDICIONES DE FUNCIONAMIENTO EN INCUBADORAS NEONATALES A TRAVÉS DE INTERNET DE LAS COSAS IoT. Universidad del Rosario.spa
dc.relation.referencesNachabe, L., Girod-Genet, M., ElHassan, B., & Jammas, J. (2015). M-health application for neonatal incubator signals monitoring through a CoAP-based multi-agent system. International Conference on Advances in Biomedical Engineering.spa
dc.relation.referencesPardell, X. (23 de Septiembre de 2023). Apuntes de Electromedicina. Recuperado el 25 de Septiembre de 2023, de https://www.pardell.es/incubadora-neonatal.html#:~:text=Las%20incubadoras%20se%20clasifican%20en,Incubadoras%20Estacionarias.&text=Incubadoras%20de%20Traslado.,fuera%20de%20la%20unidad%20m%C3%A9dica.spa
dc.relation.referencesPratap, N. L., Anuroop, K., Devi, P. N., Sandeep, A., & Nalajala, S. (2021). IoT based Smart Cradle for Baby Monitoring System. Proceedings of the Sixth International Conference on Inventive Computation Technologies.spa
dc.relation.referencesRadhika, B., & Sheshagiri, R. (2019). Incubator Baby Parameter Sensing and Monitoring. International Journal of Innovative Technology and Exploring Engineering.spa
dc.relation.referencesRajalakshmi, A., Sunitha, D., & Venkataraman, D. (2019). A Survey on Neonatal Incubator Monitoring System. Journal of Physics: Conference Series.spa
dc.relation.referencesYi Villamizar, C. D., & Vera Amador, N. (2024). DISEÑO DEL SISTEMA DE CONTROL DE TEMPERATURA PARA UN PROTOTIPO DE UNA INCUBADORA ABIERTA DE UNA IPS DE ALTA COMPLEJIDAD. Bucaramanga: UNAB.spa
dc.relation.uriapolohttps://apolo.unab.edu.co/en/persons/lusvin-javier-amado-forerospa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rights.localAbierto (Texto Completo)spa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.subject.keywordsRemote controlspa
dc.subject.keywordsRemote monitoringspa
dc.subject.keywordsNeonatesspa
dc.subject.keywordsSoftwarespa
dc.subject.keywordsPrototype developmentspa
dc.subject.keywordsElectronic surveillancespa
dc.subject.keywordsBioengineeringspa
dc.subject.keywordsBiomedical engineeringspa
dc.subject.keywordsInternet of thingsspa
dc.subject.keywordsDevices with integrated Internetspa
dc.subject.keywordsVital signspa
dc.subject.lembDesarrollo de prototiposspa
dc.subject.lembVigilancia electrónicaspa
dc.subject.lembBioingenieríaspa
dc.subject.lembIngeniería biomédicaspa
dc.subject.lembInternet de las cosasspa
dc.subject.lembDispositivos con Internet integradospa
dc.subject.lembSignos vitalesspa
dc.subject.proposalTelecontrolspa
dc.subject.proposalTelevigilanciaspa
dc.subject.proposalNeonatosspa
dc.titleDesarrollo de un prototipo de sistema para el telecontrol y televigilancia de temperatura de incubadora abierta de una IPS de alta complejidadspa
dc.title.translatedDevelopment of a prototype system for remote control and temperature monitoring of an open incubator in a high-complexity healthcare institution.spa
dc.type.coarhttp://purl.org/coar/resource_type/c_bdcc
dc.type.coarversionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
dc.type.driverinfo:eu-repo/semantics/masterThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesisspa
dc.type.redcolhttp://purl.org/redcol/resource_type/TM

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Tesis.pdf
Tamaño:
2.46 MB
Formato:
Adobe Portable Document Format
Descripción:
Tesis
Cargando...
Miniatura
Nombre:
Licencia.pdf
Tamaño:
325.78 KB
Formato:
Adobe Portable Document Format
Descripción:
Licencia

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
829 B
Formato:
Item-specific license agreed upon to submission
Descripción: