Estudio exergoambiental de una central térmica con un mejoramiento del sistema de enfriamiento del aire de admisión aprovechando los gases de salida de la turbina
| dc.contributor.advisor | Díaz González, Carlos Alirio | spa |
| dc.contributor.author | Gómez Garnica, Saray Gisella | spa |
| dc.contributor.author | Hernández Barajas, Johana Marcela | spa |
| dc.contributor.cvlac | Díaz González, Carlos Alirio [0000785806] | * |
| dc.contributor.googlescholar | Díaz González, Carlos Alirio [nqw4a5gAAAAJ&hl=es&authuser=1] | |
| dc.contributor.researchgate | Díaz González, Carlos Alirio [Carlos-Diaz-6] | |
| dc.contributor.researchgroup | Grupo de Investigación Recursos, Energía, Sostenibilidad - GIRES | spa |
| dc.contributor.researchgroup | Grupo de Investigaciones Clínicas | spa |
| dc.coverage.campus | UNAB Campus Bucaramanga | spa |
| dc.coverage.spatial | Magdalena (Colombia) | spa |
| dc.coverage.temporal | 2019 | spa |
| dc.date.accessioned | 2020-08-03T17:55:03Z | |
| dc.date.available | 2020-08-03T17:55:03Z | |
| dc.date.issued | 2019 | |
| dc.degree.name | Ingeniero en Energía | spa |
| dc.description.abstract | En este proyecto se propone realizar el estudio exergo ambiental una central térmica ubicada en el Magdalena Medio, la cual funciona en un ciclo simple con un sistema de enfriamiento evaporativo convencional que no mejora el desempeño de la turbina a condiciones de alta temperatura donde está ubicada. Para aprovechar los gases de escape de la turbina que aún tienen gran potencial energético se plantea la implementación de un chiller de absorción el cual hará que el agua de trabajo en el enfriamiento evaporativo tenga una menor temperatura para retirar mayor calor del aire de entrada y así obtener un mejor desempeño. Se plantea la simulación de cuatro casos, los dos mencionados anteriormente y otros dos a condiciones ISO y zona de ubicación, utilizando la herramienta computacional Aspen Hysys. Con los resultados obtenidos se realiza el estudio de impactos ambientales relacionados al desempeño de la planta con la operación del chiller de absorción, posteriormente se lleva a cabo una comparación de dichos impactos teniendo en cuenta las configuraciones mencionadas | spa |
| dc.description.abstractenglish | In this project it is proposed to carry out the environmental exerge study to a thermal power plant located in Colombian Magdalena Medio, which operates in a simple cycle with a conventional evaporative cooling system that does not improve the performance of the turbine at high temperature conditions where it is located. To take advantage of the turbine exhaust gasses that still have great energy potential, the implementation of an absorption chiller is proposed, which will make the working water in the evaporative cooling have a lower temperature to remove more heat from the inlet air and thus get a better performance. Four simulation cases are proposed, the two former mentioned before and another two to ISO conditions and location area, using the AspenHysys computational tool. With the results obtained in the simulation, the study of environmental impacts related to the performance of the plant with the operation of the absorption chiller, subsequently a comparison of mentiones impacts is carried out taking into account the mentioned configurations | eng |
| dc.description.degreelevel | Pregrado | spa |
| dc.description.learningmodality | Modalidad Presencial | spa |
| dc.description.tableofcontents | 1. MARCO REFERENCIAL 6 1.1. TURBINA DE GAS 6 1.1.1. Ciclo Brayton (ideal y real) 6 1.1.2. Partes principales de una turbina de gas 8 1.1.2.1. Admisión de aire 9 1.1.2.2. Compresor de aire 9 1.1.2.3. Cámara de combustión 9 1.1.2.4. Turbina de expansión 9 1.1.3. Refrigeración en el aire de admisión de las turbinas de gas 10 1.1.3.1. Influencia de la temperatura de admisión sobre el gasto másico del compresor 10 1.1.3.2. Influencia de la temperatura de admisión sobre el trabajo específico 10 1.1.3.3. Influencia de la temperatura de admisión sobre la temperatura de escape de la turbina. 10 1.2. ENFRIAMIENTO EVAPORATIVO 10 1.3. MÁQUINA DE ABSORCIÓN DE SIMPLE EFECTO 11 1.3.1. Funcionamiento y componente de una máquina de absorción de ciclo simple 12 1.4. CONTEXTO AMBIENTAL 12 1.4.1. Contaminantes producidos por las centrales térmicas a base de las turbinas de gas 13 1.4.2. Efectos en la salud 13 1.5. ASPEN HYSYS 14 1.6. MÉTODO RECIPE 2016 14 1.7. ANÁLISIS EXERGOAMBIENTAL 14 2. OBJETIVOS 15 2.1. OBJETIVO GENERAL 15 2.2. OBJETIVOS ESPECÍFICOS 15 3. METODOLOGÍA 16 3.1. FASE 1: ESTABLECIMIENTO DE LA CONDICIÓN ACTUAL DE LA CENTRAL TÉRMICA 16 3.2. FASE 2: REALIZACIÓN DEL ANÁLISIS EXERGÉTICO PARA LOS CASOS PLANTEADOS 17 3.3. FASE 3: REALIZACIÓN DEL ANÁLISIS AMBIENTAL PARA LOS CASOS PLANTEADOS 17 3.4. FASE 4: COMPARACIÓN DE INDICADORES EXERGOAMBIENTALES PARA LOS CASOS PLANTEADOS 17 4. DESARROLLO 18 4.1. SIMULACIÓN EN HYSYS DEL CASO EN CONDICIONES ISO Y ZONA CÁLIDA 19 4.1.1. Condiciones ISO 19 4.1.2. Condiciones zona cálida 22 4.2. SIMULACIÓN EN HYSYS DE LOS CASOS SISTEMA DE ENFRIAMIENTO ACTUAL Y EL PROPUESTO PARA MODIFICAR 24 4.2.1. Sistema de enfriamiento actual (Cooler) 24 4.2.2. Sistema de enfriamiento modificado (Chiller de absorción) 26 4.2.3. Análisis exergético para cada caso (ISO, zona cálida, sistema de enfriamiento actual y modificado) 29 4.2.3.1. Cálculo de entalpias y entropías 30 4.2.3.2. Análisis exergético 30 4.3. SIMULACIÓN EN SIMAPRO DE LOS CASOS (ISO, ZONA CÁLIDA, SISTEMA DE ENFRIAMIENTO ACTUAL Y MODIFICADO) 34 4.3.1. Simulación del funcionamiento de la turbina de gas en SimaPro 34 4.3.2. Simulación del funcionamiento del chiller de absorción acoplado a la turbina de gas en SimaPro 37 4.3.3. Análisis ambiental para cada caso (ISO, zona cálida, sistema de enfriamiento actual y modificado) 39 4.4. ANÁLISIS EXERGOAMBIENTAL DE LOS CASOS (ISO, ZONA CÁLIDA, SISTEMA DE ENFRIAMIENTO ACTUAL Y MODIFICADO) 39 5. RESULTADOS 43 5.1. SIMULACIÓN HYSYS PARA LOS CASOS PLANTEADOS 43 5.2. ANÁLISIS EXERGÉTICO PARA LOS CASOS PLANTEADOS 46 5.3. ANÁLISIS AMBIENTAL PARA LOS CASOS PLANTEADOS 51 5.4. ANÁLISIS EXERGOAMBIENTAL PARA LOS CASOS PLANTEADOS 52 6. CONCLUSIONES 58 7. RECOMENDACIONES 60 8. BIBLIOGRAFIA 61 | spa |
| dc.format.mimetype | application/pdf | spa |
| dc.identifier.instname | instname:Universidad Autónoma de Bucaramanga - UNAB | spa |
| dc.identifier.reponame | reponame:Repositorio Institucional UNAB | spa |
| dc.identifier.repourl | repourl:https://repository.unab.edu.co | spa |
| dc.identifier.uri | http://hdl.handle.net/20.500.12749/7142 | |
| dc.language.iso | spa | spa |
| dc.publisher.grantor | Universidad Autónoma de Bucaramanga UNAB | spa |
| dc.publisher.program | Pregrado Ingeniería en Energía | spa |
| dc.relation.references | A. D. Coronel, E. Del, and E. D. E. Las, “Estudio del efecto de las condiciones atmosféricas sobre las prestaciones de una turbina de gas,” 2016. | spa |
| dc.relation.references | A. M. Blanco-Marigorta, M. Masi, and G. Manfrida, “Exergo-environmental analysis of a reverse osmosis desalination plant in Gran Canaria,” Energy, vol. 76. pp. 223–232, 2014. | spa |
| dc.relation.references | A. Paula, P. Santos, C. R. Andrade, and E. L. Zaparoli, “Comparison of Different Gas Turbine Inlet Air Cooling Methods,” World Acad. Sci. Eng. Technol., vol. 6, no. 1, pp. 40–45, 2012. | spa |
| dc.relation.references | Á. Restrepo and E. Bazzo, “Co-firing: An exergoenvironmental analysis applied to power plants modified for burning coal and rice straw,” Renew. Energy, vol. 91, pp. 107–119, 2016. | spa |
| dc.relation.references | Ambientum, “Los contaminantes atmosféricos - Enciclopedia Medioambiental,” Ambientum. | spa |
| dc.relation.references | AspenTech, “Aspen HYSYS - Operations Guide,” AspenTech, p. 1527, 2005. | spa |
| dc.relation.references | B. D. E. L. Vallès, “De Agua Por Ciclo De Absorción ,” 2014. | spa |
| dc.relation.references | C. Gonzalez Sabogal and E. Pabon Sanchez, “Simulacion de procesos de lixiviacion,” Revista ION, vol. 12, no. 1. pp. 129–136, 1990. | spa |
| dc.relation.references | C. S. A. Agudelo Santamaría, J. Agudelo Santamaría, “Efecto de la altitud en el análisis termoeconómico de un sistema de cogeneración.,” vol. 74, pp. 113–124, 2007. | spa |
| dc.relation.references | “CAPÍTULO 3 EL MÉTODO DE ANÁLISIS EXERGÉTICO - PDF.” . | spa |
| dc.relation.references | central termica de ciclo Combinado, “El Ciclo Brayton,” Ciclo Brayton. 2002. | spa |
| dc.relation.references | D. I. G. Herrera, “Trabajo de grado para optar por el título de Ingeniera Ambiental y Sanitario,” 2007. | spa |
| dc.relation.references | D. J. N. Gámez, “Análisis de las tecnologías para disminuir la temperatura del aire en la succión del compresor y su influencia sobre los indicadores energéticos en una planta de cogeneradora con turbina a gas (TG) y generador de vapor de recuperador de calor (HRSG’s),” p. 2011, 2011. | spa |
| dc.relation.references | E. Pyzik, S. Jarz, ˛ Ebowski, and A. Miller, “Impact of inlet air cooling on gas turbine performance,” Open Access J. J. Power Technol., vol. 92, no. 4, pp. 249–257, 2012. | spa |
| dc.relation.references | F. Fern and L. Tutor, “Trabajo Fin de Grado Grado en Ingeniería de la Energía Sistemas de tratamiento del aire de admisión de las turbinas de gas,” 2016. | spa |
| dc.relation.references | “Funcionamiento del ciclo de absorción de simple efecto con bromuro de litio y agua, alimentado por agua caliente | Absorsistem.” . | spa |
| dc.relation.references | G. Industriales, “Especial Turbinas de Gas,” Energiza.org, 2011. | spa |
| dc.relation.references | G. P. Prim, “Resumen,” 2016. | spa |
| dc.relation.references | J. M. C. P. Carolina Sierra Rubio, “Análisis exergético de una planta de producción de biodiesel de aceite de palma,” 2011. | spa |
| dc.relation.references | Laverdad.es, “El gas natural es el combustible con menor impacto ambiental.” 2018. | spa |
| dc.relation.references | M. Alhazmy, “Limitations of Inlet Air Evaporative Cooling System for Enhancing Gas Turbine Performance in Hot and Humid Climates,” Int. J. Energy Power Eng., vol. 4, no. 5, p. 287, 2016. | spa |
| dc.relation.references | Manual MSD, “Intercambio de oxígeno y dióxido de carbono - Trastornos del pulmón y las vías respiratorias - Manual MSD versión para público general,” Manual Msd. p. 1, 2012. | spa |
| dc.relation.references | Munters, “Evaporative Cooling Increases Gas Turbine Power Output - Case Studies.” . | spa |
| dc.relation.references | N. Omar, M. Sahril, T. H. Khai, M. Kamarul, Y. Yusof, and J. Fournier, “ScienceDirect ScienceDirect ScienceDirect Feasibility Study of Turbine Inlet Air Cooling using Mechanical Chillers in Malaysia Climate Assessing the feasibility of using the heat demand-outdoor Shahrul temperature function for a Asmara district heat deman,” Energy Procedia, vol. 138, pp. 558–563, 2017. | spa |
| dc.relation.references | PRéConsultants, “ReCiPe | PRé Sustainability.” . | spa |
| dc.relation.references | R. P. O. R. Absorción, “4. estado del arte de las máquinas de refrigeración por absorción. 4.1.” | spa |
| dc.relation.references | R. Rajoria and A. khan, “Analysis of Effects of Evaporative Inlet Cooling on Gas Turbines,” Int. J. Eng. Trends Technol., vol. 37, no. 2, pp. 57–61, 2016. | spa |
| dc.relation.references | “Sistemas de Enfriamiento - Turbinas de Gas.” . | spa |
| dc.relation.references | T. J. Kotas, The exergy method of thermal plant analysis, vol. 20. 1985. | spa |
| dc.relation.references | “The New Era of Absorption Chillers - Power Engineering.” | spa |
| dc.relation.references | Y. Chang and J. Dyment, “Jump Start Guide : Acid Gas Cleaning in Aspen HYSYS ® A Brief Tutorial ( and supplement to and online documentation ),” 2018. | spa |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
| dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 2.5 Colombia | * |
| dc.rights.local | Abierto (Texto Completo) | spa |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | * |
| dc.subject.keywords | Energy engineering | eng |
| dc.subject.keywords | Gas turbine | eng |
| dc.subject.keywords | Evaporative cooling | eng |
| dc.subject.keywords | Absorption chiller | eng |
| dc.subject.keywords | Environmental impact | eng |
| dc.subject.lemb | Innovaciones tecnológicas | spa |
| dc.subject.lemb | Exergía | spa |
| dc.subject.lemb | Centrales termoeléctricas | spa |
| dc.subject.proposal | Ingeniería en energía | spa |
| dc.subject.proposal | Turbina de gas | spa |
| dc.subject.proposal | Enfriamiento evaporativo | spa |
| dc.subject.proposal | Chiller de absorción | spa |
| dc.subject.proposal | Impacto ambiental | spa |
| dc.title | Estudio exergoambiental de una central térmica con un mejoramiento del sistema de enfriamiento del aire de admisión aprovechando los gases de salida de la turbina | spa |
| dc.title.translated | Environmental exergue study of a thermal power plant with an improvement of the intake air cooling system taking advantage of the turbine exhaust gases | eng |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.driver | info:eu-repo/semantics/bachelorThesis | |
| dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
| dc.type.local | Trabajo de Grado | spa |
| dc.type.redcol | http://purl.org/redcol/resource_type/TP |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- 2019_Tesis_Saray_Gisella_Gomez_Garnica.pdf
- Tamaño:
- 2.33 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Tesis
Cargando...
- Nombre:
- 2019_Presentacion_Saray_Gisella_Gomez_Garnica.pdf
- Tamaño:
- 1.89 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Presentación
Cargando...
- Nombre:
- 2019_Licencia_Saray_Gomez.pdf
- Tamaño:
- 588.33 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Licencia
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: